Deskripsi
HI-5522 adalah instrumen bench top kelas tinggi yang mengukur tujuh parameter. Ini menggabungkan saluran ganda dengan input probe suhu terpisah dan mendukung elektroda referensi eksternal yang dibutuhkan oleh sensor pH setengah sel.
Solusi Industri Anda
Hubungi kami untuk informasi dan penawaran produk:
Whatsapp: 0821-6277-6495 (Adhitya)
HI-5522 adalah instrumen bench top kelas tinggi yang mengukur tujuh parameter. Ini menggabungkan saluran ganda dengan input probe suhu terpisah dan mendukung elektroda referensi eksternal yang dibutuhkan oleh sensor pH setengah sel.
pH - Range | -2.0 to 20.0 pH; -2.00 to 20.00; -2.000 to 20.000 pH | |
Resolution | 0.1 pH; 0.01 pH; 0.001 pH | |
Accuracy | ±0.1 pH; ±0.01 pH; ±0.002 pH ± 1 LSD | |
Calibration | automatic, up to five-point calibration, eight standard buffers available, and five custom buffers | |
Temperature Compensation | automatic or manual from -20.0 to 120.0°C | |
mV - Range | ±2000 mV | |
Resolution | 0.1 mV | |
Accuracy | ±0.2 mV ± 1 LSD | |
ISE - Range | 1 x 10-6 to 9.99 x 1010 concentration | |
Resolution | 1; 0.1; 0.01; 0.001 concentration | |
Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) | |
Calibration | automatic, up to five-point calibration, five fixed standard solutions available for each measurement unit, and five user efined standards | |
Temperature - Range | -20.0 to 120.0°C | |
Resolution | 0.1°C | |
Accuracy | ±0.2°C (without probe) | |
EC - Range | 0.000 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm absolute EC | |
Resolution | 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm | |
Accuracy | ±1% of reading (±0.01µS/cm) | |
Cell Constant | 0.0500 to 200.00 | |
Cell Type | 4 cells | |
Calibration | automatic standard recognition, user standard single point/multi-point calibration | |
Calibration Reminder | yes | |
Temperature Coefficient | 0.00 to 10.00%/°C | |
Temperature Compensation | disabled, linear and non-linear (natural water) | |
Reference Temperature | 5.0 to 30.0°C | |
Profiles | up to 10, 5 each channel | |
USP Compliant | yes | |
TDS - Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt actual TDS (with 1.00 factor) | |
Resolution | 0.001 ppm; 0. 01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt; 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt | |
Accuracy | ±1% of reading (±0.01 ppm) | |
Resistivity - Range | 1.0 to 99.9 Ω • cm; 100 to 999 Ω • cm; 1.00 to 9.99 KΩ • cm; 10.0 to 99.9 KΩ • cm; 100 to 999 KΩ • 1.00 to 9.99 M Ω •cm; 10.0 to 100.0 MΩ • cm | |
Resolution | 0.1 Ω •cm; 1 Ω • cm; 0.01 K Ω •cm; 0.1 K Ω •cm; 1 KΩ • cm; 0.01 MΩ • cm; 0.1 MΩ • cm | |
Accuracy | ±2% of reading (± 1 Ω • cm) | |
Salinity - Range | practical scale: 0.00 to 42.00 psu; natural sea water scale: 0.00 to 80.00 ppt; percent scale: 0.0 to 400.0% NaCl | |
Resolution | 0.01 for practical scalenatural sea water scale; 0.1% for percent scale | |
Accuracy | ±1% of reading | |
Calibration | percent-scale one point (with HI-7037 standard) | |
pH electrode | HI-1131B glass body pH electrode with BNC connector and 1m cable (included) | |
EC Probe | HI-76312 platinum, four-ring EC/TDS probe with a 1m cable (included) | |
Temperature Probe | HI-7662-T stainless steel temperature probe with 1m cable (included) | |
Input Channel (s) | 1 pH/ORP + 1 EC | |
GLP | cell constant, reference temperature/coefficient, calibration points, calibration time stamp, probe offset for conductivity | |
Logging | record: 100,000 data point storage/channel, up to 100 lots with max, 50,000 records/lot; Interval: settable between 1 second and max log time of 180 minutes; Type: automatic, manual, AutoHOLD | |
Display | colour graphic LCD with on-screen help, graphing, and custom colour configuration | |
PC Connection | USB | |
Power Supply | 12 VDC adapter (included) | |
Environment | 0 to 50°C; RH max 95% non-condensing | |
Dimensions/Weight | 160 x 231 x 94 mm/1.2 kg |